CloudEngine S6750-H36C — 36 × 100GE Aggregation Switch in 1U



Learn More


Aggregation layers in large campuses usually run out of rack space before they run out of bandwidth. The S6750-H36C answers that directly: thirty-six 100GE QSFP28 ports in a single rack unit, 8 Tbps of system switching capacity, and dual pluggable 1200 W power supplies for 1+1 redundancy — all in a chassis 43.6 mm tall.

What separates it from a generic high-density switch is MACsec. Ethernet frames are authenticated, encrypted, integrity-checked and protected against replay at the link layer, which is what government, banking and defence tenders in the Kingdom increasingly ask for by name. Note the constraint: MACsec runs on ports 1–16 or ports 25–36, so the encrypted links must be planned into the port map at design stage, not patched in afterwards.

Specifications



ModelCloudEngine S6750-H36C
Fixed ports36 × 40/100 GE QSFP28
Port layout32 × 40/100 GE QSFP28 + 4 × 40/100 GE QSFP28 uplink
Switching capacity7.2 Tbps device / 8 Tbps system
Dimensions (H × W × D)43.6 × 442.0 × 420.0 mm
Chassis height1U
Chassis weight (incl. packaging)11 kg
Power supply1200 W AC or 1200 W DC, pluggable, 1+1 backup
Rated voltageAC 100–240 V, 50/60 Hz · HVDC 240 V DC · DC −48 to −60 V
Maximum voltage rangeAC 90–290 V, 45–65 Hz · HVDC 190–290 V DC · DC −38.4 to −72 V
Typical power consumption537 W (30% traffic, ATIS standard, dual power modules)
Maximum power consumption558 W (100% traffic) · 679 W at 45 °C with long-distance optics
Operating temperature−5 °C to +45 °C
Storage temperature−40 °C to +70 °C
Relative humidity5% to 95%, non-condensing
Noise (acoustic power)57.7 dB(A) normal · 86.4 dB(A) at high temperature
Heat dissipationAir cooling, intelligent fan speed adjustment
Surge protectionAC modules ±6 kV differential and common mode · DC modules ±2 kV differential, ±4 kV common
MAC entries512K maximum
VLANs4K
SecurityMACsec (ports 1–16 or 25–36), NAC, RADIUS, HWTACACS, IPv6 RA Guard, secure boot

Capabilities

AreaSupport
RoutingIPv4 — RIP, OSPF, IS-IS, BGP · IPv6 — RIPng, OSPFv3, ISISv6, BGP4+ · VRF, policy-based routing
OverlayVXLAN centralised and distributed gateway, BGP-EVPN, NETCONF configuration
Segment routingSRv6 BE (L3 EVPN), BGP EVPN, SRv6 via NETCONF
MPLSMPLS-LDP, MPLS-L3VPN, MPLS QoS
Loop protectionSTP, RSTP, MSTP, G.8032 ERPS, Huawei SEP (switching within 50 ms)
ReliabilityM-LAG, iStack, LACP, E-Trunk, VRRP with BFD, Smart Link, Eth-OAM 802.1ag
QoSPQ, DRR, WDRR, PQ+DRR, PQ+WDRR · WRED and tail drop · eight queues per interface · network slicing
MonitoringNative-IP IFIT, streaming telemetry, iPCA, NetStream, NQA, RMON
ManagementHuawei cloud platform, iMaster NCE-Campus, OPS Python scripting, HOUP intelligent upgrade

Licensing: feature-based licensing or Huawei N1 mode, in three tiers — N1 Basic (Layer 2, IPv4, IPv6), N1 Foundation (adds NE management and user access authentication via iMaster NCE-Campus), N1 Advanced (adds VXLAN, Free Mobility, iPCA and CampusInsight).

Where it fits best

Aggregation layer in large enterprise campuses, universities and data centres — and in particular any deployment where encrypted links are a tender requirement. Two numbers deserve attention before the room is chosen: the 45 °C operating ceiling, and the 86.4 dB(A) noise figure at high temperature. This switch belongs in a properly cooled room, not a converted office cupboard.

Service: Fast Vision supplies, configures, stacks and warranties this switch as an authorised Huawei distributor in Saudi Arabia.

Related products